{"id":686683,"date":"2024-02-05T12:14:02","date_gmt":"2024-02-05T12:14:02","guid":{"rendered":"https:\/\/www.abnewswire.com\/pressreleases\/?p=686683"},"modified":"2024-02-05T12:14:02","modified_gmt":"2024-02-05T12:14:02","slug":"meet-trouble-with-the-solenoid-valve-this-common-fault-solution-can-help-you-well","status":"publish","type":"post","link":"https:\/\/www.abnewswire.com\/pressreleases\/meet-trouble-with-the-solenoid-valve-this-common-fault-solution-can-help-you-well_686683.html","title":{"rendered":"Having Trouble With The Solenoid Valve? This Common Fault &#038; Solution Can Help Users Well"},"content":{"rendered":"<p><img decoding=\"async\" class=\"alignnone size-full wp-image-3823\" src=\"https:\/\/c206.goodao.net\/uploads\/\u5fae\u4fe1\u56fe\u72473.jpg\" alt=\"summary\" \/><\/p>\n<table border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"104\"><strong>Faults<\/strong><\/td>\n<td valign=\"top\" width=\"113\"><strong>Reasons<\/strong><\/td>\n<td valign=\"top\" width=\"236\"><strong>Manifestation<\/strong><\/td>\n<td valign=\"top\" width=\"100\"><strong>Solution<\/strong><\/td>\n<\/tr>\n<tr>\n<td rowspan=\"7\" valign=\"top\" width=\"104\">Cannot open&nbsp;<\/td>\n<td valign=\"top\" width=\"113\">1. The inlet valve is unopen<\/td>\n<td valign=\"top\" width=\"236\">The solenoid coil is working but has no water flow<\/td>\n<td valign=\"top\" width=\"100\">Open the inlet valve&nbsp;<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">2. The controller has a command fault<\/td>\n<td valign=\"top\" width=\"236\">The solenoid coil is unworking, the multiline system can open the valve by using the test contact<\/td>\n<td valign=\"top\" width=\"100\">Check the controller&rsquo;s procedural setting<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">3. The control circuit is breakdown<\/td>\n<td valign=\"top\" width=\"236\">The controller screen shows a warning message;&nbsp;The solenoid coil is unworking;&nbsp;The valve works normally when you loosen the solenoid assembly manually<\/td>\n<td valign=\"top\" width=\"100\">Use the multimeter to check if the control line is a short circuit or open circuit and repair<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">4. The flow handle is unopen<\/td>\n<td valign=\"top\" width=\"236\">The controller screen shows valve is open;&nbsp;The solenoid coil is working;&nbsp;Cannot open the valve even when you loosen the solenoid assembly manually<\/td>\n<td valign=\"top\" width=\"100\">Twist the flow handle to a suitable position<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">5. The solenoid coil is breakdown<\/td>\n<td valign=\"top\" width=\"236\">The controller screen shows a warning message;&nbsp;The solenoid coil is unworking;&nbsp;The valve works normally when you loosen the solenoid assembly manually;&nbsp;The control line is tested normally<\/td>\n<td valign=\"top\" width=\"100\">Replace the new solenoid coil<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">6. The pipe is plugged<\/td>\n<td valign=\"top\" width=\"236\">The controller screen shows valve is open;&nbsp;The solenoid coil is working;&nbsp;Cannot open the valve even when adjusting the flow handle or loosening the solenoid assembly manually<\/td>\n<td valign=\"top\" width=\"100\">Clean the impurities in the pipe<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">7. Wrong installing direction<\/td>\n<td valign=\"top\" width=\"236\">The <a rel=\"nofollow\" title=\"INOVATO T SERIES SOLENOID VALVE\" href=\"https:\/\/c206.goodao.net\/inovato-t-series-solenoid-valve-product\/\">solenoid valve<\/a> is closed when the controller turns on, and the <a rel=\"nofollow\" title=\"Y SERIES SOLENOID VALVE OEM SERIES\" href=\"https:\/\/c206.goodao.net\/y-series-solenoid-valve-oem-series-product\/\">solenoid valve<\/a> is open or occasionally open when the controller turns off<\/td>\n<td valign=\"top\" width=\"100\">Reinstallation&nbsp;<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"6\" valign=\"top\" width=\"104\">Cannot close&nbsp;<\/td>\n<td valign=\"top\" width=\"113\">1. The solenoid coil is loosened<\/td>\n<td valign=\"top\" width=\"236\">The solenoid coil is working;&nbsp;The solenoid coil connector has overflowed<\/td>\n<td valign=\"top\" width=\"100\">Tighten up the solenoid coil and replace the plug seal<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">2. The pipe is plugged or broken<\/td>\n<td valign=\"top\" width=\"236\">The controller cannot close;&nbsp;But can close by using a flow handle<\/td>\n<td valign=\"top\" width=\"100\">Clean the impurities in the pipe<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">3.&nbsp;The flow handle is twisted to the maximum<\/td>\n<td valign=\"top\" width=\"236\">The controller can close by reducing the flow handle appropriately<\/td>\n<td valign=\"top\" width=\"100\">Twist the flow handle to the appropriate position<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">4. The diaphragm is broken<\/td>\n<td valign=\"top\" width=\"236\">The valve cannot close even when twisting the flow handle to the minimum<\/td>\n<td valign=\"top\" width=\"100\">Replace the diaphragm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">5. Impurities are under the diaphragm<\/td>\n<td valign=\"top\" width=\"236\">The valve cannot close even when twisting the flow handle to the minimum<\/td>\n<td valign=\"top\" width=\"100\">Open the valve and clean the impurities<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"113\">6. Wrong installing direction<\/td>\n<td valign=\"top\" width=\"236\">The <a rel=\"nofollow\" title=\"INOVATO Y SERIES SOLENOID VALVE\" href=\"https:\/\/c206.goodao.net\/inovato-y-series-solenoid-valve-product\/\">solenoid valve<\/a> is closed when the controller turns on, and the solenoid valve is open or occasionally open when the controller turns off<\/td>\n<td valign=\"top\" width=\"100\">Reinstallation&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><a rel=\"nofollow\" href=\"https:\/\/c206.goodao.net\/uploads\/\u56fe\u72475.jpg\"><img decoding=\"async\" class=\"alignnone size-full wp-image-3824\" src=\"https:\/\/c206.goodao.net\/uploads\/\u56fe\u72475.jpg\" alt=\"\u56fe\u72475\" \/><\/a><\/p>\n<p><span style='font-size:18px !important;'>Media Contact<\/span><br \/><strong>Company Name:<\/strong> <a href=\"https:\/\/www.abnewswire.com\/companyname\/inovato-zm.com_117435.html\" rel=\"nofollow\">Yuyao Sun-rainman Irrigation Equipment Factory<\/a><br \/><strong>Email:<\/strong> <a href=\"https:\/\/www.abnewswire.com\/email_contact_us.php?pr=meet-trouble-with-the-solenoid-valve-this-common-fault-solution-can-help-you-well\" rel=\"nofollow\">Send Email<\/a><br \/><strong>Country:<\/strong> China<br \/><strong>Website:<\/strong> <a href=\"https:\/\/www.inovato-zm.com\/\" target=\"_blank\" rel=\"nofollow\">https:\/\/www.inovato-zm.com\/<\/a><\/p>\n<p><object type=\"text\/html\" data=\"https:\/\/www.inovato-zm.com\/\" style=\"width:900px; height:400px;\"><\/object><img decoding=\"async\" src=\"https:\/\/www.abnewswire.com\/press_stat.php?pr=meet-trouble-with-the-solenoid-valve-this-common-fault-solution-can-help-you-well\" alt=\"\" width=\"1px\" height=\"1px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Faults Reasons Manifestation Solution Cannot open&nbsp; 1. The inlet valve is unopen The solenoid coil is working but has no water flow Open the inlet valve&nbsp; 2. The controller has a command fault The solenoid coil is unworking, the multiline &hellip; <a href=\"https:\/\/www.abnewswire.com\/pressreleases\/meet-trouble-with-the-solenoid-valve-this-common-fault-solution-can-help-you-well_686683.html\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[417,423,422,404,416],"tags":[],"class_list":["post-686683","post","type-post","status-publish","format-standard","hentry","category-Marketing-Sales","category-Professional-Services","category-Retail","category-US","category-World"],"_links":{"self":[{"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/posts\/686683","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/comments?post=686683"}],"version-history":[{"count":0,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/posts\/686683\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/media?parent=686683"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/categories?post=686683"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/tags?post=686683"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}