{"id":644339,"date":"2023-03-27T11:00:02","date_gmt":"2023-03-27T11:00:02","guid":{"rendered":"https:\/\/www.abnewswire.com\/pressreleases\/?p=644339"},"modified":"2023-03-27T11:00:02","modified_gmt":"2023-03-27T11:00:02","slug":"learning-more-about-drop-ftth-cable-patch-cord-standard","status":"publish","type":"post","link":"https:\/\/www.abnewswire.com\/pressreleases\/learning-more-about-drop-ftth-cable-patch-cord-standard_644339.html","title":{"rendered":"Learning More About Drop FTTH cable patch cord standard"},"content":{"rendered":"<p style=\"text-align: justify;\">\uff33\uff23\/A\uff30\uff23Pre-Connectorized&nbsp;<a rel=\"nofollow\" href=\"https:\/\/www.gdtxcable.com\/ftth-flat-drop-cable\/\" target=\"_blank\">Optical&nbsp;Fiber&nbsp;Drop&nbsp;Cable<\/a>&nbsp;Test&nbsp;method&nbsp;1&nbsp;Terms&nbsp;and&nbsp;definitions<\/p>\n<p style=\"text-align: justify;\"><a rel=\"nofollow\" href=\"https:\/\/cdn.globalso.com\/gdtxcable\/ddedbc37.jpg\"><img decoding=\"async\" src=\"https:\/\/cdn.globalso.com\/gdtxcable\/ddedbc37.jpg\" alt=\"212\" \/><\/a><\/p>\n<p style=\"text-align: justify;\">1.1<\/p>\n<p style=\"text-align: justify;\">Name:Pre-Connectorized&nbsp;Optical&nbsp;Fiber&nbsp;Drop&nbsp;Cable<\/p>\n<p style=\"text-align: justify;\">1.2&nbsp;&nbsp;Requirement&nbsp;of&nbsp;Pre-Connectorized&nbsp;Optical&nbsp;Fiber&nbsp;Drop&nbsp;Cable<\/p>\n<p style=\"text-align: justify;\">1.3&nbsp;&nbsp;Structure&nbsp;Requirements<\/p>\n<p style=\"text-align: justify;\">Pre-Connectorized Optical Fiber Drop Cable is composed of butterfly type introduction cable and fiber optic removable connector plug.<\/p>\n<p style=\"text-align: justify;\">According&nbsp;to&nbsp;the&nbsp;structure&nbsp;classification,&nbsp;it&nbsp;can&nbsp;be&nbsp;divided&nbsp;into:&nbsp;single-end&nbsp;prefabricated&nbsp;end&nbsp;type&nbsp;and&nbsp;double-end&nbsp;prefabricated&nbsp;end&nbsp;type.&nbsp;The&nbsp;schematic&nbsp;diagram&nbsp;of&nbsp;the&nbsp;structure&nbsp;is&nbsp;shown&nbsp;in&nbsp;Figure&nbsp;1&nbsp;and&nbsp;Figure&nbsp;2.<\/p>\n<p style=\"text-align: justify;\">&nbsp;<\/p>\n<p style=\"text-align: justify;\">1.4&nbsp;&nbsp;&nbsp;Requirements&nbsp;for&nbsp;optical&nbsp;Fiber&nbsp;Connector&nbsp;Plugs<\/p>\n<p style=\"text-align: justify;\">1.4.1&nbsp;&nbsp;Requirements&nbsp;on&nbsp;the&nbsp;Size&nbsp;of&nbsp;the&nbsp;Optical&nbsp;Fiber&nbsp;connector<\/p>\n<p style=\"text-align: justify;\">The length of the Pre-Connectorized Optical Fiber Drop Cable plug (including the protection sleeve) should not be greater than 60mm, which is shown in Figure 3.<\/p>\n<p style=\"text-align: justify;\">Interface graphics and matching size should meet the requirements IEC 61754,YD\/T 1272.3-2005<\/p>\n<p style=\"text-align: justify;\">&nbsp;<\/p>\n<p style=\"text-align: justify;\">1.4.2&nbsp;&nbsp;&nbsp;Requirements&nbsp;for&nbsp;the&nbsp;End&nbsp;face&nbsp;of&nbsp;the&nbsp;Connector<\/p>\n<p style=\"text-align: justify;\">The&nbsp;end&nbsp;faces&nbsp;of&nbsp;optical&nbsp;fiber&nbsp;connectors&nbsp;are&nbsp;classified&nbsp;into&nbsp;the&nbsp;following&nbsp;2&nbsp;types<\/p>\n<p style=\"text-align: justify;\">a\uff09&nbsp;UPC&nbsp;type&nbsp;\uff1aA&nbsp;pin&nbsp;body&nbsp;with&nbsp;a&nbsp;spherical&nbsp;polishing&nbsp;surface&nbsp;and&nbsp;achieving&nbsp;physical&nbsp;contact&nbsp;(UPC)&nbsp;is&nbsp;provided<\/p>\n<p style=\"text-align: justify;\">b\uff09&nbsp;APC&nbsp;type&nbsp;\uff1aA&nbsp;pin&nbsp;body&nbsp;with&nbsp;an&nbsp;8&nbsp;degree&nbsp;oblique&nbsp;spherical&nbsp;polishing&nbsp;surface&nbsp;(APC8&deg;)&nbsp;and&nbsp;physical<\/p>\n<p style=\"text-align: justify;\">contact&nbsp;is&nbsp;achieved&nbsp;The&nbsp;end&nbsp;face&nbsp;of&nbsp;the&nbsp;insert&nbsp;body&nbsp;should&nbsp;meet&nbsp;the&nbsp;requirements&nbsp;of&nbsp;IEC&nbsp;61754,YD\/T&nbsp;2152-2010\u3002<\/p>\n<p style=\"text-align: justify;\">1.4.3&nbsp;&nbsp;Structural&nbsp;Requirements for&nbsp;the&nbsp;Connector&nbsp;of&nbsp;the&nbsp;Optical&nbsp;Fiber<\/p>\n<p style=\"text-align: justify;\">&nbsp;<\/p>\n<div class=\"table_wrap\" style=\"text-align: justify;\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"140\">1:Ferrule<\/td>\n<td valign=\"top\" width=\"114\">2.inner&nbsp;body<\/td>\n<td valign=\"top\" width=\"109\">3.outer&nbsp;body<\/td>\n<td valign=\"top\" width=\"68\">4.Spring<\/td>\n<td valign=\"top\" width=\"127\">5.Set&nbsp;head&nbsp;block<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"140\">6.Metal&nbsp;tail&nbsp;handle<\/td>\n<td valign=\"top\" width=\"114\">7.crimp&nbsp;contact<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"177\">8.The&nbsp;tail&nbsp;sheath<\/td>\n<td valign=\"top\" width=\"127\">9.FTTH&nbsp;cable<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: justify;\">The connection between the optical fiber connector plug and the ftth cable should be firm and reliable. The connection relay of the riveting pressure connector shouldact on the sheath and strengthening members of the ftth cable, should not deal with the optical fiber core in the ftth cable to impose long-term stress.<\/p>\n<p style=\"text-align: justify;\">The optical fiber connector used for optical cable connection should be fixed at the end of the cable.<\/p>\n<p style=\"text-align: justify;\">This fixation can not affect the normal axial range of movement of the pin body, but also bear a certain tension.<\/p>\n<p style=\"text-align: justify;\">When the tail cable is subjected to a normal pulling force of no less than 9.8N, the pin body cannot be pulled back to ensure the normal operation of the connector.<\/p>\n<p style=\"text-align: justify;\">1.5&nbsp;&nbsp;&nbsp;FTTH&nbsp;cable&nbsp;requirements<\/p>\n<p style=\"text-align: justify;\">FTTH cable introduction shall meet the requirements of Q\/CT 2348.<\/p>\n<p style=\"text-align: justify;\">The optical fiber should be a single-mode optical fiber conforming to ITU-T G.657A standard<\/p>\n<p style=\"text-align: justify;\">1.6&nbsp;&nbsp;The&nbsp;length&nbsp;of&nbsp;Pre-Connectorized&nbsp;Optical&nbsp;Fiber&nbsp;Drop&nbsp;Cable<\/p>\n<p style=\"text-align: justify;\">Pre-Connectorized Optical Fiber Drop Cable should be able to be delivered in accordance with the requirements of the customized length, it is recommended to customize according to the step length of 5m or 10m , such as: 20 m, 25 m, 30 m, 35 m, 50m 70m 100m etc<\/p>\n<p style=\"text-align: justify;\">1.7&nbsp;&nbsp;Environment&nbsp;Requirements<\/p>\n<p style=\"text-align: justify;\">a\uff09&nbsp;Operating&nbsp;temperature\uff1a-40\u2103\uff5e+70\u2103\u3002<\/p>\n<p style=\"text-align: justify;\">b\uff09&nbsp;Storage&nbsp;temperature\uff1a-40\u2103\uff5e+70\u2103\u3002<\/p>\n<p style=\"text-align: justify;\">c\uff09&nbsp;Relative&nbsp;humidity\uff1a&le;95\uff05\uff08+30\u2103\u65f6\uff09&nbsp;\u3002<\/p>\n<p style=\"text-align: justify;\">d\uff09&nbsp;Barometric&nbsp;pressure\uff1a62kPa\uff5e106kPa\u3002<\/p>\n<p style=\"text-align: justify;\">1.8&nbsp;&nbsp;Material&nbsp;Requirements<\/p>\n<p style=\"text-align: justify;\">The&nbsp;materials&nbsp;used&nbsp;should&nbsp;meet&nbsp;the&nbsp;following&nbsp;requirements\uff1a<\/p>\n<p style=\"text-align: justify;\">a)&nbsp;&nbsp;&nbsp;The&nbsp;combustion&nbsp;performance&nbsp;of&nbsp;the&nbsp;plastic&nbsp;parts&nbsp;&nbsp;used&nbsp;for&nbsp;&nbsp;Pre-Connectorized&nbsp;Optical&nbsp;Fiber&nbsp;&nbsp;Drop<\/p>\n<p style=\"text-align: justify;\">Cable SC plug should conform to the provisions of GB\/T 5169.5-2008 &lt;&gt;, and the duration of the test flame is 10 seconds.<\/p>\n<p style=\"text-align: justify;\">b) The sheath of FTTH Cable shall be made of flame retardant material, and its flame retardant performance shall meet the requirements of 6.4.4.3 in Q\/CT 2348-2011 &lt;&gt;.<\/p>\n<p style=\"text-align: justify;\">c) Two strengthening members shall be symmetrically placed on the FTTH cable, and the requirements of strengthening members shall meet the requirements of 6.1.4 in Q\/CT 2348-2011.<\/p>\n<p style=\"text-align: justify;\">d) Pre-Connectorized Optical Fiber Drop Cable can withstand the required test conditions, the adhesive used to make SC plug has no adverse effect on the plug structure, its physical, chemical and optical properties should match the butterfly introduction cable, must not damage the optical properties of the prefabricated end butterfly introduction cable.<\/p>\n<p style=\"text-align: justify;\">e) Comply with RoHS standards, can not pollute the environment, in line with environmental protection standards.<\/p>\n<p style=\"text-align: justify;\">f) When the finished product is damaged, its components are not allowed to cause harm to people<\/p>\n<p style=\"text-align: justify;\">2&nbsp;&nbsp;Performance&nbsp;requirement<\/p>\n<p style=\"text-align: justify;\">2.1&nbsp;&nbsp;Optical&nbsp;Performance&nbsp;Requirements<\/p>\n<p style=\"text-align: justify;\">Table1Optical&nbsp;performance&nbsp;requirements<\/p>\n<div class=\"table_wrap\" style=\"text-align: justify;\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"47\">\n<p align=\"center\">NO<\/p>\n<\/td>\n<td valign=\"top\" width=\"150\">\n<p align=\"center\">Test<\/p>\n<\/td>\n<td valign=\"top\" width=\"109\">\n<p align=\"center\">L&le;20m<\/p>\n<\/td>\n<td valign=\"top\" width=\"119\">\n<p align=\"center\">20m&lt;L&le;50m<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p align=\"center\">50m&lt;L&le;100m<\/p>\n<\/td>\n<td valign=\"top\" width=\"121\">\n<p align=\"center\">100m&lt;L&le;200m<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"47\">\n<p align=\"center\">a<\/p>\n<\/td>\n<td valign=\"top\" width=\"150\">\n<p align=\"center\">Insertion&nbsp;loss(1310nm)1<\/p>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"349\">\n<p align=\"center\">&le;0.3dB<\/p>\n<\/td>\n<td valign=\"top\" width=\"121\">\n<p align=\"center\">&le;0.34dB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"47\">\n<p align=\"center\">b<\/p>\n<\/td>\n<td valign=\"top\" width=\"150\">\n<p align=\"center\">Insertion&nbsp;loss(1550nm)2<\/p>\n<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"349\">\n<p align=\"center\">&le;0.3dB<\/p>\n<\/td>\n<td valign=\"top\" width=\"121\">\n<p align=\"center\">&le;0.32dB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"47\">\n<p align=\"center\">c<\/p>\n<\/td>\n<td valign=\"top\" width=\"150\">\n<p align=\"center\">Return&nbsp;Loss(UPC)3<\/p>\n<\/td>\n<td valign=\"top\" width=\"109\">\n<p align=\"center\">&ge;47dB<\/p>\n<\/td>\n<td valign=\"top\" width=\"119\">\n<p align=\"center\">&ge;46dB<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p align=\"center\">&ge;45dB<\/p>\n<\/td>\n<td valign=\"top\" width=\"121\">\n<p align=\"center\">&ge;44dB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"47\">\n<p align=\"center\">d<\/p>\n<\/td>\n<td valign=\"top\" width=\"150\">\n<p align=\"center\">Return&nbsp;Loss(APC)4<\/p>\n<\/td>\n<td valign=\"top\" width=\"109\">\n<p align=\"center\">&ge;55dB<\/p>\n<\/td>\n<td valign=\"top\" width=\"119\">\n<p align=\"center\">&ge;51dB<\/p>\n<\/td>\n<td valign=\"top\" width=\"120\">\n<p align=\"center\">&ge;49dB<\/p>\n<\/td>\n<td valign=\"top\" width=\"121\">\n<p align=\"center\">&ge;46dB<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td colspan=\"6\" valign=\"top\" width=\"669\">1More&nbsp;than&nbsp;200m&nbsp;Insertion&nbsp;loss&nbsp;\uff08&nbsp;1310nm\uff09\uff1a0.30dB&nbsp;+&nbsp;L&times;0.36dB\/1000m2More&nbsp;than&nbsp;200m&nbsp;Insertion&nbsp;loss&nbsp;\uff08&nbsp;1550nm\uff09\uff1a0.30dB&nbsp;+&nbsp;L&times;0.22dB\/1000m3More&nbsp;than&nbsp;200m&nbsp;&nbsp;&nbsp;&nbsp;Return&nbsp;Loss&nbsp;\uff08&nbsp;UPC\uff09\uff1a&ge;40dB4More&nbsp;than&nbsp;200m&nbsp;&nbsp;&nbsp;&nbsp;Return&nbsp;Loss&nbsp;\uff08APC\uff09\uff1a&ge;40dB<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: justify;\">2.2&nbsp;&nbsp;&nbsp;Environmental&nbsp;Performance&nbsp;Requirements<\/p>\n<p style=\"text-align: justify;\">The Pre-Connectorized Optical Fiber Drop Cable shall meet the environmental performance test requirements specified in Table 2 and the optical performance requirements specified in Table 1.<\/p>\n<p style=\"text-align: justify;\">Table&nbsp;2&nbsp;Environmental&nbsp;Performance&nbsp;Requirements<\/p>\n<div class=\"table_wrap\" style=\"text-align: justify;\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td rowspan=\"2\" valign=\"top\" width=\"23\">\n<p align=\"center\">NO<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"top\" width=\"88\">\n<p align=\"center\">Test<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"top\" width=\"152\">\n<p align=\"center\">Test&nbsp;condition<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"489\">\n<p align=\"center\">Requirements<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"76\">\n<p align=\"center\">Change&nbsp;ininsertion&nbsp;loss\uff08dB\uff09<\/p>\n<\/td>\n<td valign=\"top\" width=\"413\">\n<p align=\"center\">Shape&nbsp;change<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"23\">\n<p align=\"center\">a<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">high&nbsp;temperature<\/p>\n<\/td>\n<td valign=\"top\" width=\"152\">+70\u2103&nbsp;96h&nbsp;Test&nbsp;optical&nbsp;performance<\/td>\n<td valign=\"top\" width=\"76\">\n<p align=\"center\">&le;0.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"413\">No mechanical damage,&nbsp;such as&nbsp;deformation, Cracking, relaxation and&nbsp;other&nbsp;phenomena<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"23\">\n<p align=\"center\">b<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">low&nbsp;temperature<\/p>\n<\/td>\n<td valign=\"top\" width=\"152\">-40\u2103&nbsp;96hTest&nbsp;optical&nbsp;performance<\/td>\n<td valign=\"top\" width=\"76\">\n<p align=\"center\">&le;0.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"413\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as&nbsp;deformation,Cracking,&nbsp;relaxation and&nbsp;other&nbsp;phenomena<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"23\">\n<p align=\"center\">c<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">Temperature&nbsp;cycle<\/p>\n<\/td>\n<td valign=\"top\" width=\"152\">(&nbsp;40\u2103~70\u2103) 2121&nbsp;times&nbsp;cycle,&nbsp;168h<\/td>\n<td valign=\"top\" width=\"76\">\n<p align=\"center\">&le;0.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"413\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as&nbsp;deformation,Cracking,&nbsp;relaxation&nbsp;and other&nbsp;phenomena<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"23\">\n<p align=\"center\">d<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">Damp&nbsp;and&nbsp;hot<\/p>\n<\/td>\n<td valign=\"top\" width=\"152\">+40\u2103&nbsp;95\uff05,&nbsp;96h&nbsp;Test&nbsp;optical&nbsp;performance<\/td>\n<td valign=\"top\" width=\"76\">\n<p align=\"center\">&le;0.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"413\">No&nbsp;mechanical damage, such as&nbsp;deformation,Cracking, relaxation&nbsp;and other&nbsp;phenomena<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"23\">\n<p align=\"center\">e<\/p>\n<\/td>\n<td valign=\"top\" width=\"88\">\n<p align=\"center\">In&nbsp;water<\/p>\n<\/td>\n<td valign=\"top\" width=\"152\">Room&nbsp;&nbsp;&nbsp;temperature,&nbsp;water168h<\/td>\n<td valign=\"top\" width=\"76\">\n<p align=\"center\">&le;0.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"413\">No&nbsp;deformation,&nbsp;foaming,&nbsp;roughness,&nbsp;Peeling&nbsp;and&nbsp;other&nbsp;phenomena<\/td>\n<\/tr>\n<tr>\n<td colspan=\"5\" valign=\"top\" width=\"754\">Note:&nbsp;4.6~4.12&nbsp;for&nbsp;specific&nbsp;test&nbsp;conditions&nbsp;and&nbsp;methods<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: justify;\">2.3&nbsp;&nbsp;Mechanical&nbsp;Performance&nbsp;Requirements<\/p>\n<p style=\"text-align: justify;\">Comply&nbsp;Q\/CT&nbsp;2348-2011\u300aTechnical&nbsp;requirements&nbsp;for&nbsp;the&nbsp;introduction&nbsp;of&nbsp;butterfly&nbsp;optical&nbsp;cable&nbsp;by&nbsp;China&nbsp;Telecom&nbsp;users\u300b.Table1<\/p>\n<p style=\"text-align: justify;\">Table1&nbsp;Mechanical&nbsp;requirements&nbsp;Test&nbsp;methods<\/p>\n<div class=\"table_wrap\" style=\"text-align: justify;\">\n<table border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td rowspan=\"2\" valign=\"top\" width=\"25\">\n<p align=\"center\">NO<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"top\" width=\"68\">\n<p align=\"center\">Test<\/p>\n<\/td>\n<td rowspan=\"2\" valign=\"top\" width=\"324\">\n<p align=\"center\">Test&nbsp;condition<\/p>\n<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"333\">Requirements<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"79\">Change&nbsp;ininsertion&nbsp;loss\uff08dB\uff09<\/td>\n<td valign=\"top\" width=\"253\">Shape&nbsp;change&nbsp;and&nbsp;other&nbsp;standards&nbsp;after&nbsp;test<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"25\">\n<p align=\"center\">a<\/p>\n<\/td>\n<td valign=\"top\" width=\"68\">\n<p align=\"center\">Vibration<\/p>\n<\/td>\n<td valign=\"top\" width=\"324\">Frequency: 10-55Hz; Sweep frequency: sweep frequency once&nbsp;\/min,&nbsp;frequency range&nbsp;45Hz;Amplitude:&nbsp;0.75mm&nbsp;single&nbsp;amplitude;Time:&nbsp;2&nbsp;hours&nbsp;in&nbsp;each&nbsp;direction;<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">&le;0.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"253\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as&nbsp;deformation,&nbsp;cracking,&nbsp;relaxation,&nbsp;etc<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"25\">\n<p align=\"center\">b<\/p>\n<\/td>\n<td valign=\"top\" width=\"68\">\n<p align=\"center\">Drop<\/p>\n<\/td>\n<td valign=\"top\" width=\"324\">Height: 1.5m&nbsp;from&nbsp;the&nbsp;sample&nbsp;head;Times:&nbsp;8&nbsp;times;<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">&le;0.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"253\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as&nbsp;deformation,&nbsp;cracking,&nbsp;relaxation,&nbsp;etc<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"25\">\n<p align=\"center\">c<\/p>\n<\/td>\n<td valign=\"top\" width=\"68\">\n<p align=\"center\">Repeatability<\/p>\n<\/td>\n<td valign=\"top\" width=\"324\">Insert&nbsp;and&nbsp;unplug: 10times<\/td>\n<td valign=\"top\" width=\"79\">\n<p align=\"center\">&le;0.2<\/p>\n<\/td>\n<td valign=\"top\" width=\"253\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as&nbsp;deformation,&nbsp;cracking,&nbsp;relaxation,&nbsp;etc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: justify;\">&nbsp;<\/p>\n<div class=\"table_wrap\" style=\"text-align: justify;\">\n<table border=\"0\" cellspacing=\"0\" cellpadding=\"0\">\n<colgroup>\n<col span=\"5\" width=\"72\" \/><\/colgroup>\n<tbody>\n<tr>\n<td width=\"72\" height=\"127\">d<\/td>\n<td width=\"72\">Mechanicaldurability<\/td>\n<td width=\"72\">Insert&nbsp;and&nbsp;unplug\uff1a500times<\/td>\n<td width=\"72\">&le;0.2<\/td>\n<td width=\"72\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as&nbsp;deformation,&nbsp;cracking,&nbsp;relaxation,&nbsp;etc<\/td>\n<\/tr>\n<tr>\n<td width=\"72\" height=\"234\">e<\/td>\n<td width=\"72\">Tensile<\/td>\n<td width=\"72\">Between&nbsp;plug&nbsp;and&nbsp;cable:Load:50,&nbsp;Test&nbsp;optical&nbsp;performance\uff0c10min\uff1b&nbsp;Load:60N\uff0cTest&nbsp;optical&nbsp;performance, 10min;<\/td>\n<td width=\"72\">&le;0.2<\/td>\n<td width=\"72\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as deformation, cracking,&nbsp;relaxation,&nbsp;etc<\/td>\n<\/tr>\n<tr>\n<td width=\"72\" height=\"127\">f<\/td>\n<td width=\"72\">Torsion<\/td>\n<td width=\"72\">load: 50N; Rate: 10times\/min;times: 200\uff1b<\/td>\n<td width=\"72\">&le;0.2<\/td>\n<td width=\"72\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as&nbsp;&nbsp;deformation,&nbsp;cracking,&nbsp;relaxation,&nbsp;etc<\/td>\n<\/tr>\n<tr>\n<td width=\"72\" height=\"253\">g<\/td>\n<td width=\"72\">Plug,&nbsp;pull&nbsp;force<\/td>\n<td width=\"72\">Force&nbsp;measuring&nbsp;instrument;<\/td>\n<td width=\"72\">&mdash;&mdash;<\/td>\n<td width=\"72\">No&nbsp;mechanical&nbsp;damage,&nbsp;suchas&nbsp;&nbsp;deformation, cracking,&nbsp;relaxation, etc&nbsp;insertion&nbsp;force\uff1a&le;19.6N&nbsp;;withdrawal&nbsp;force\uff1a&le;19.6N.<\/td>\n<\/tr>\n<tr>\n<td width=\"72\" height=\"127\">h<\/td>\n<td width=\"72\">Tensile strength&nbsp;of locking&nbsp;mechanism<\/td>\n<td width=\"72\">Load: 40N; Time: 10min\uff1b<\/td>\n<td width=\"72\">&le;0.2<\/td>\n<td width=\"72\">No&nbsp;mechanical&nbsp;damage,&nbsp;such&nbsp;as deformation,&nbsp;cracking,&nbsp;relaxation,&nbsp;etc<\/td>\n<\/tr>\n<tr>\n<td width=\"72\" height=\"181\">i<\/td>\n<td width=\"72\">Insert&nbsp;elastic&nbsp;fatigue&nbsp;resistance<\/td>\n<td width=\"72\">Point&nbsp;H=6.9&nbsp;mmPress&nbsp;the&nbsp;number&nbsp;of&nbsp;times500times;<\/td>\n<td width=\"72\">&le;0.2<\/td>\n<td width=\"72\">No mechanical damage, the&nbsp;core can return to the&nbsp;original&nbsp;datum&nbsp;position<\/td>\n<\/tr>\n<tr>\n<td height=\"19\">&nbsp;<\/td>\n<td>&nbsp;<\/td>\n<td>&nbsp;<\/td>\n<td>&nbsp;<\/td>\n<td>&nbsp;<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p style=\"text-align: justify;\">2.4&nbsp;&nbsp;Package&nbsp;and&nbsp;Transportation<\/p>\n<p style=\"text-align: justify;\">Pre-Connectorized Optical Fiber Drop Cable Test method shall be equipped with dust caps. Each prefabricated end type butterfly introduction cable shall have independent packaging coil, coil diameter shall not be less than 25 times the diameter of the tail cable.<\/p>\n<p style=\"text-align: justify;\">The package should be marked with product model, production batch, production date, manufacturer&rsquo;s name and implementation standard number.<\/p>\n<p style=\"text-align: justify;\">2.5&nbsp;&nbsp;Storage<\/p>\n<p style=\"text-align: justify;\">Pre-Connectorized Optical Fiber Drop Cable can not be placed in the open air or serious corrosion environment for a long time, should be stored within the storage temperature range.<\/p>\n<p><span style='font-size:18px !important;'>Media Contact<\/span><br \/><strong>Company Name:<\/strong> <a href=\"https:\/\/www.abnewswire.com\/companyname\/gdtxcable.com_111900.html\" rel=\"nofollow\">Hangzhou Guangdian Communication Technology Co., Ltd.<\/a><br \/><strong>Email:<\/strong> <a href=\"https:\/\/www.abnewswire.com\/email_contact_us.php?pr=learning-more-about-drop-ftth-cable-patch-cord-standard\" rel=\"nofollow\">Send Email<\/a><br \/><strong>Country:<\/strong> China<br \/><strong>Website:<\/strong> <a href=\"https:\/\/www.gdtxcable.com\/\" target=\"_blank\" rel=\"nofollow\">https:\/\/www.gdtxcable.com\/<\/a><\/p>\n<p><object type=\"text\/html\" data=\"https:\/\/www.gdtxcable.com\/\" style=\"width:900px; height:400px;\"><\/object><img decoding=\"async\" src=\"https:\/\/www.abnewswire.com\/press_stat.php?pr=learning-more-about-drop-ftth-cable-patch-cord-standard\" alt=\"\" width=\"1px\" height=\"1px\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\uff33\uff23\/A\uff30\uff23Pre-Connectorized&nbsp;Optical&nbsp;Fiber&nbsp;Drop&nbsp;Cable&nbsp;Test&nbsp;method&nbsp;1&nbsp;Terms&nbsp;and&nbsp;definitions 1.1 Name:Pre-Connectorized&nbsp;Optical&nbsp;Fiber&nbsp;Drop&nbsp;Cable 1.2&nbsp;&nbsp;Requirement&nbsp;of&nbsp;Pre-Connectorized&nbsp;Optical&nbsp;Fiber&nbsp;Drop&nbsp;Cable 1.3&nbsp;&nbsp;Structure&nbsp;Requirements Pre-Connectorized Optical Fiber Drop Cable is composed of butterfly type introduction cable and fiber optic removable connector plug. According&nbsp;to&nbsp;the&nbsp;structure&nbsp;classification,&nbsp;it&nbsp;can&nbsp;be&nbsp;divided&nbsp;into:&nbsp;single-end&nbsp;prefabricated&nbsp;end&nbsp;type&nbsp;and&nbsp;double-end&nbsp;prefabricated&nbsp;end&nbsp;type.&nbsp;The&nbsp;schematic&nbsp;diagram&nbsp;of&nbsp;the&nbsp;structure&nbsp;is&nbsp;shown&nbsp;in&nbsp;Figure&nbsp;1&nbsp;and&nbsp;Figure&nbsp;2. &nbsp; 1.4&nbsp;&nbsp;&nbsp;Requirements&nbsp;for&nbsp;optical&nbsp;Fiber&nbsp;Connector&nbsp;Plugs 1.4.1&nbsp;&nbsp;Requirements&nbsp;on&nbsp;the&nbsp;Size&nbsp;of&nbsp;the&nbsp;Optical&nbsp;Fiber&nbsp;connector The length of the Pre-Connectorized Optical Fiber Drop Cable plug (including the protection &hellip; <a href=\"https:\/\/www.abnewswire.com\/pressreleases\/learning-more-about-drop-ftth-cable-patch-cord-standard_644339.html\">Continue reading <span class=\"meta-nav\">&rarr;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[410,417,423,413,416],"tags":[],"class_list":["post-644339","post","type-post","status-publish","format-standard","hentry","category-Manufacturing-Industry","category-Marketing-Sales","category-Professional-Services","category-Services","category-World"],"_links":{"self":[{"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/posts\/644339","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/comments?post=644339"}],"version-history":[{"count":0,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/posts\/644339\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/media?parent=644339"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/categories?post=644339"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.abnewswire.com\/pressreleases\/wp-json\/wp\/v2\/tags?post=644339"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}